Which model's published watt rating and documented outlet labels fit the equipment you plan to connect?
Products compared

ASIN B00429N19W
CyberPower CP1500PFCLCDa (CP1500PFCLCDA)
After accounting for startup draw and your chosen operating headroom, the load is above 900 W but remains within CyberPower's 1000 W published rating.
Last observed offer
$239.95
List Price: $274.95
- Confirm offer eligibility on Amazon
Size: 1500VA
Price checked
Observed condition: new. Coupon and subscription requirements unverified.

ASIN B08GRY1W93
APC Back-UPS Pro BR1500MS2
Your verified connected load fits within 900 W and APC's six standard plus four surge-only receptacles cover the plan after you confirm the standard outlets meet any battery-backup requirement. If CyberPower also fits, the available facts do not establish an APC feature advantage; compare the exact current offers and other verified constraints.
Last observed offer
$299.99
List Price: $339.99
- Confirm offer eligibility on Amazon
Size: 1500VA
Price checked
Observed condition: new. Coupon and subscription requirements unverified.
Prices are per listed package. Pickoryx may earn a commission from qualifying purchases through the paid Amazon links on this page, at no added cost to you.
Published by Pickoryx · Published 2026-10-22 · Source checked 2026-10-22 04:38 UTC
The main trade-off
Both are 1500 VA units. CyberPower publishes a 1000 W rating and explicitly labels six battery-and-surge outlets plus six surge-only outlets. APC publishes 900 W and lists six standard outlets plus four surge-only outlets; its cited datasheet does not label the six standard outlets as battery-backed.
Quick verdict
Both are 1500 VA, 120 V tower UPS models, but CyberPower publishes 1000 W and APC publishes 900 W. CyberPower explicitly lists six battery-and-surge outlets plus six surge-only; APC's datasheet lists six standard outlets plus four surge-only, without labeling the standard outlets as battery-backed.
Choose CyberPower CP1500PFCLCDa (CP1500PFCLCDA) if
- After accounting for startup draw and your chosen operating headroom, the load is above 900 W but remains within CyberPower's 1000 W published rating.
- You need more than four surge-only receptacles; CyberPower explicitly lists six.
Choose APC Back-UPS Pro BR1500MS2 if
- Your verified connected load fits within 900 W and APC's six standard plus four surge-only receptacles cover the plan after you confirm the standard outlets meet any battery-backup requirement. If CyberPower also fits, the available facts do not establish an APC feature advantage; compare the exact current offers and other verified constraints.
When the recommendation changes
- Recheck the choice if the equipment list, measured watt draw, startup behavior, the number of surge-only sockets, or which devices must use battery-backed sockets changes. Confirm APC's six standard outlets meet any battery-backup need before relying on that outlet plan.
The differences that matter
| Decision point | CyberPower CP1500PFCLCDa (CP1500PFCLCDA) | APC Back-UPS Pro BR1500MS2 |
|---|---|---|
| Connected Load Rating Fit | 1500 VA / 1000 W, 120 V nominal input; the exact page is headed CP1500PFCLCDa and names CP1500PFCLCDA in the box contents.[1] | 1500 VA / 900 W output at 120 V for BR1500MS2.[2] |
What this changes: The 1500 VA labels match, but the watt ratings do not. Compare actual connected watts with each watt rating; do not treat VA as watts or assume the rating alone establishes runtime, startup suitability, or a preferred safety margin.[1, 2] The better fit depends on your priorities | ||
| Battery Backed And Surge Socket Allocation | 12 NEMA 5-15R outlets: 6 battery-and-surge protected and 6 surge-only.[1] | 10 NEMA 5-15R outlets: 6 standard outlets and 4 additional surge-only outlets. The cited datasheet does not label the six standard outlets as battery-backed.[2] |
What this changes: CyberPower explicitly labels six battery-and-surge outlets and six surge-only outlets; APC's datasheet lists six standard outlets plus four surge-only outlets. The labels alone do not establish that APC's six standard outlets are battery-backed. If battery-backup count is decisive, verify that outlet class in APC's manual or on the exact unit before buying. For surge-only needs, CyberPower documents two more sockets.[1, 2] The better fit depends on your priorities | ||
Best for your routine
After accounting for startup draw and chosen operating headroom, a measured load exceeds 900 W but remains at or below CyberPower's 1000 W published rating.
Best fit: CyberPower CP1500PFCLCDa (CP1500PFCLCDA)
Based on listed features, not comparative testing.
The published rating gives CyberPower a 1000 W ceiling versus APC's 900 W. This is a rating-fit distinction, not a runtime or real-world performance result; the complete load and startup draw still need to fit within the selected model's limit.
A layout needs more than four surge-only receptacles, while no more than six devices need the battery-and-surge outlets CyberPower explicitly lists.
Best fit: CyberPower CP1500PFCLCDa (CP1500PFCLCDA)
Based on listed features, not comparative testing.
CyberPower explicitly lists six battery-and-surge outlets and six surge-only outlets; APC lists six standard plus four surge-only. CyberPower is the documented fit when more than four surge-only sockets are needed. Do not assume APC's six standard outlets are battery-backed without confirming their class.
What the evidence cannot decide
- A setup is within 900 W and needs no more than four surge-only sockets; any required battery-backed outlet count on APC has been confirmed for the exact model.: The published watt rating and outlet labels may fit this configuration once APC's standard outlet class is confirmed for any battery-backup requirement. Both units can satisfy the stated load and surge-only count, so the evidence does not support preferring APC; compare the exact current offers or another verified requirement.
Value and trade-offs
One or both observed offers have eligibility conditions, so no unrestricted price difference is shown.
Either model's higher current offer should be justified by the watt ceiling or outlet plan your equipment needs. If both fit, the cited facts do not establish an APC-specific feature advantage; check exact current seller, condition and offer terms.
Price history is insufficient to recommend buying now or waiting; compare the current offers without a timing call.
Limitations
- This comparison uses manufacturer-published ratings and outlet labels; it does not establish runtime for a particular load, transfer behavior in your equipment, or data-loss prevention.
- Measure connected equipment and check device-specific startup requirements before choosing a capacity. The cited ratings alone do not determine an appropriate operating margin.
- CyberPower says package contents can vary by region. Confirm the package and included accessories on the exact offer before purchase.
- APC's cited datasheet is dated March 12, 2021; it identifies BR1500MS2 specifications and is not evidence of a current offer or seller condition.
- APC's datasheet calls six outlets standard and four surge-only; it does not identify the six standard outlets as battery-backed. Verify that outlet class in the official manual or on the exact unit if battery backup is important.
- Price history is not available for a timing assessment; changing current offers may be displayed separately.
Questions shoppers ask
Do the extra CyberPower outlets also provide battery backup?
CyberPower's manufacturer page explicitly lists six battery-and-surge-protected outlets and six surge-only outlets. APC's datasheet lists six standard outlets plus four surge-only outlets, but does not label its six standard outlets as battery-backed. Verify that outlet class in APC's manual or on the exact unit if battery backup is required. CyberPower documents two more surge-only sockets.
Which unit should I choose if both say 1500 VA?
Use the watt rating as well as the VA figure. CyberPower publishes 1000 W for this exact model and APC publishes 900 W for BR1500MS2. Compare those limits with measured equipment load, separately check startup requirements, and verify which APC outlets provide battery backup if that affects your plan.
Methodology and sources
Compared the exact 120 V models by their stated watt and VA ratings, then kept each manufacturer's outlet labels distinct: CyberPower explicitly identifies battery-and-surge and surge-only outlets, while APC's cited datasheet lists standard and surge-only outlets. No device load or outage runtime was tested.
Research assistance was used to locate and organize the cited product information; the comparison is limited to those published specifications.
View 2 sources
- 1.CP1500PFCLCDaCyberPower · Official specifications · Source checked 2026-10-22 04:20 UTC
Evidence used on this page
- Specifications: Capacity (VA), Capacity (Watts), Nominal Input Voltage, Outlet(s) - Total, Outlet(s) - Battery & Surge Protected, Outlet(s) - Surge-Only Protected; What's in the box: The exact manufacturer page identifies CP1500PFCLCDa, lists 1500 VA, 1000 W and 120 V, and specifies 12 NEMA 5-15R outlets split into six battery-and-surge protected and six surge-only; the box list names CP1500PFCLCDA. It notes contents may vary by region.
- 2.BR1500MS2 Back UPS PRO Product Data SheetSchneider Electric / APC · Official support · Source checked 2026-10-22 04:20 UTC
Evidence used on this page
- Printed page 1: output W/VA and socket-outlet specification: six NEMA 5-15R standard outlets plus four NEMA 5-15R surge-only outlets; document dated March 12, 2021: The exact BR1500MS2 datasheet identifies 120 V, 900 W and 1500 VA. Its outlet specification lists six standard NEMA 5-15R outlets plus four additional NEMA 5-15R surge-only outlets; the datasheet does not label the six standard outlets as battery-backed.